  • External full maintenance bypass panels, 3Ø
  • 2 breaker, 3 breaker & custom configurations
  • UL 489 circuit protection, UL1778 UPS application
  • NEMA 1 wall & floor mountings
  • Make-before-break design; Kirk-Key© type safety interlocks; solenoid key release (SKRU) as standard
  • Shunt Trip & EPO interface as standard
  • 208, 360, 480 50/60Hz VAC operation
  • 150A-1200A for 30kVA to 750kVA UPS in stock
  • expanded capacities available upon request

 

400A 3CB MBP Oultine (typical) PDF documents open with Adobe reader

400A 3CB MBP Wiring Diagram PDF documents open with Adobe reader

Bypass Sizing Guide PDF documents open with Adobe reader

Maintenance Bypass Panel - External UPS

                                   

 

Wall-Mount Nema Configuration Bypass Panels

Make-before-break; Kirk-Key, Shunt Trip, Aux Contacts, SKRU. 35kAIC standard Free-standing floor   

when input voltage to UPS is different from output, consult with SBS engineering services

kVA

Voltage

Amperage

Round-Up

Breaker

kAIC

Height

Width

Depth

Weight

 

 

Input

Output

"AF"

"AT"

Quan

 

Inches

Inches

Inches

LBS.

 

30

208

208

150

104

2

65

74.2

31

14

382

 

 

208

208

150

104

3

65

74.2

31

14

389

 

 

480

480

100

45

2

35

74.2

31

14

382

 

 

480

480

100

45

3

35

74.2

31

14

389

 

40

208

208

150

139

2

65

74.2

31

14

382

 

 

208

208

150

139

3

65

74.2

31

14

389

 

 

480

480

100

60

2

35

74.2

31

14

382

 

 

480

480

100

60

3

35

74.2

31

14

389

 

50

208

208

250

173

2

65

74.2

31

14

382

 

 

208

208

250

173

3

65

74.2

31

14

389

 

 

480

480

150

75

2

35

74.2

31

14

382

 

 

480

480

150

75

3

35

74.2

31

14

389

 

65

208

208

250

226

2

65

74.2

31

14

382

 

 

208

208

250

226

3

65

74.2

31

14

389

 

 

480

480

150

98

2

35

74.2

31

14

382

 

 

480

480

150

98

3

35

74.2

31

14

389

 

80

208

208

400

278

2

65

82.4

40

14

560

 

 

208

208

400

278

3

65

82.4

40

14

569

 

 

480

480

150

120

2

35

74.2

31

14

382

 

 

480

480

150

120

3

35

74.2

31

14

389

 

100

208

208

400

347

2

65

82.4

40

14

560

 

 

208

208

400

347

3

65

82.4

40

14

569

 

 

480

480

150

150

2

35

74.2

31

14

382

 

 

480

480

150

150

3

35

74.2

31

14

389

 

130

208

208

600

451

2

65

90.7

40

14

597

 

 

208

208

600

451

3

65

90.7

40

14

604

 

 

480

480

250

195

2

35

74.2

31

14

382

 

 

480

480

250

195

3

35

74.2

31

14

389

 

160

208

208

600

555

2

65

90.7

40

14

597

 

 

208

208

600

555

3

65

90.7

40

14

604

 

 

480

480

250

241

2

35

74.2

31

14

382

 

 

480

480

250

241

3

35

74.2

31

14

389

 

225

208

208

800

781

2

65

90.7

40

14

597

 

 

208

208

800

781

3

65

90.7

40

14

604

 

 

480

480

400

338

2

35

82.4

40

14

560

 

 

480

480

400

338

3

35

82.4

40

14

569

 

300

480

480

600

451

2

35

90.7

40

14

597

 

 

480

480

600

451

3

35

90.7

40

14

604

 

400

480

480

600

601

2

35

90.7

40

14

597

 

 

480

480

600

601

3

35

90.7

40

14

604

 

500

480

480

800

752

2

65

90.7

40

14

608

 

 

480

480

800

752

3

65

90.7

40

14

619

 

625

480

480

1200

940

2

65

90.7

40

14

608

 

 

480

480

1200

940

3

65

90.7

40

14

619

 

750

480

480

1200

1128

2

65

90.7

40

14

608

 

 

480

480

1200

1128

3

65

90.7

40

14

619

 

 

 Most

Common

Sizes 

 

"AF" Frame Size- Trip Setting  is Less

 

 

Main Battery Disconnects

  • 24vdc - 480vdc nominal dc bus
  • Circuit breaker (UL489) or fusible
  • 100A- 4000A
  • Shunt trip (120vac), UVR(24v) & EPO (n/c) interface as standard
  • Other voltages available upon request
  • NEMA 1 wall/floor mountings
main battery disconnect, circuit breaker, 100A-4000A
 One Line MBD Dwg (typical) PDF documents open with Adobe Reader  
   

SBS MAIN BATTERY DISCONNECT SELECTION & PRICING
 
DC AMPS NOMINAL CONFIGURATION NUMBER UNDER-VOLTAGE POLES ENCLOSURE AUX SHUNT    
Vdc BUS    RELEASE     CONTACT TRIP    
100 <240v SEDA24AT0150TE100-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
150 (120 cells) SEDA24AT0150TE150-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
250 240 vdc SFHA24AT0250SF250-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
400   SGHA26AT0400SG400-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
600   SGHA26AT0600SG600-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
800   SGHA26AT0800SG600-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
1200   SGHA26AT01200SK1200-ST-UV-B1 24vdc/vac 2 NEMA1 1 120/60    
                   
100 >240v SEHA36AT0150TE100-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
150 (240 cells) SEHA36AT0150TE150-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
250 480vdc SFHA36AT0250SF250-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
400   SGHA36AT0400SG400-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
600   SGHA36AT0600SG600-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
800   SGHA36AT0800SG600-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
1200   SGHA36AT1200SK1200-ST-UV-B1 24vdc/vac 3 NEMA1 1 120/60    
                   
All battery disconnects are in UL NEMA 1 enclosure with a UL890 circuit breaker rated for 250vdc nominal,  and have both a 120/60 Shunt Trip Module (Liebert & Default) or a 24v S.T. Module (Powerware, Specify), 24Vac/dc Under-Voltage Release Module (MGE, Mitsubishi, Default) and one auxilliary contact N/C, (Default).  Two pole circuit breakers are suitable for battery systems of 125 cells or less.  Three pole breakers are designed for systems in excess of 125 cells and are to be "Series Connected" to achieve a 500vdc nominal rating.  Series connection requires that the positive conductor be routed through 2 of the 3 breaker poles.  Should you have any questions about this standard dc wiring practice, please contact SBS engineering services at 800-554-2243, xt 309; or email sbs@sbsbattery.com.  ALWAYS CHECK UPS I&O MANUAL FOR PROPER DC BREAKER RATING.  Consult factory for other configurations.
                   
                   
                   

 

 

 

 Custom Switchgear

  • generator paralleling
  • automatic transfer switches (ATS)
  • protective saftey relay design
  •  cogeneration, load shedding
  • load sharring
  • circuit protection coordination
  • programmable controllers (PLCs)
  • power metering
  • SCADA interface
 SBS paralleling switchgear  Metal Clad Low Voltage Switchgear by SBS
   

» View sub category/Products
 
Storage Battery Systems Inc.© Copyright 2006 | International (011-1-262-703-5800) | 800-554-2243 | FAX 262-703-3073 | sbs@sbsbattery.com
New York Web Design & Web Development by Flying Cow Design