SBS provides the highest-quality mission critical engineering applications and specifying services. We will install any critical data or network power system using degreed engineers & licensed trades contractors. From generators to UPS and rectifier banks to battery plant, SBS will assume total responsibility so that your cut-over occurs as scheduled.
Engineer, install or remove system solutions,
Furnish all AC or DC products nationwide
Install customer-specific equipment
Facility Concept Study (FCS)
Prior to adding or changing a power surety system or beginning a design-build construction project, you need to understand the impact and benefit. SBS provides the analytical information in a format that will streamline your bugetary request process. We will evaluate your loads, support capacities, critcal bus, protected bus & your 5 year growth plans to ascertain whether or not your existing system or space will provide the necessary support. A critical power availability and reliability assessment will be made based on the unique requirements of your business operation. Great attention will be devoted to maximizing your operational continuity while minmizing a budgetary impact. You will receive a detailed report evaluating the steps required to provision your network or data power environment including a proposed schedule, bill of materails, electrical one-line, budgetary estimate, scope of work (SOW) plus a timeline with waypoints and milestones. This impact analysis will afford C-level decisions makers the perspective required to form an intelligent approval or rejection of the concept. Should it be decided to proceed, the package is comprehensive enough to be submitted as-is for competitive bid if desired. All this is provided for an engineering design fee typically at 5% when compared to a similar report provided by an A&E firm.
Power Quality Audit
The 'Power Quality Audit' provides a non-invasive assessment of your power surety environment. Its purpose is to provide you with a 'snapshot' systemic analysis of key aspects of your critcial power system in order to evaluate your reliability/ availability relative to your expected perfromance in avoidance of downtime or unplanned outages. The PQA can be tailored for your site specific needs but offers:
Circuit protection and TVSS coordination
Single point grounding and bonding compliance
Redundancy, reliability and availability
Scalability and expandability tolerance, impact
System/component state-of-health snapshot
Preventative maintenance program evaluation bechmarked against internal or governmental standards (JIC, FRB, ANSI, IEEE, HIPPA)
Single point of failure location(s)
Outage, maintenance and failure forensics
Recommendations for repair or upgrade
Susceptible maintenance/repair issues
Replenish parts availability status
Load stress vs. capacity, 80% rule may apply
Deviation from OEM specification
Topology, design and configuration analysis
Facility Rollover/System Commissioning
SBS offers complete commissioning and start-up services for entire facilities to individual systems that may have been redeployed. These services 'prove' the operability of the utility, protected and critical load bus structures so that your uptime can be assured.
Design-Build Services
Utilizing the FCS as a foundational blueprint, SBS will finalize the project concept into a fixed and firm proposal. The requisite engineering resources, civil, electrical & mechanical, will be deployed to finalize all project details. Once again, our 'open book' philosophy allows us to offer a complete project on a 'cost plus' basis agreeing on a mutually acceptable margin for our services. For small to medium construction projects, SBS can be an extremely cost effective solution. Using a blend of local, licensed trades, SBS service technicians, SBS engineers, local specialist as needed & SBS on-site construction project managers, the initiative is certain to complete in a timely & professional manner.
Network & Data Center Relocation Services
Moving a data center to a new facility presents an extremely challenging task. Who do you entrust to rig & move sensitive IT & power electronic devices? The answer is a firm that understands mission critical power & the loads it protects. With SBS, you can be assured that great care will be given the the network devices & associted critical power components during their removal & reinstallation. Only SBS will recommission the system with you to guarantee that it is working properly as before the move. SBS knows precisely what components require special handling in order to remain operational. SBS knows the original factory specification to which the system must perform. Our mission-critical move will:
Evaluate current system operational, parameters
Prepare new site for physical electrical landing
Decommission and electrically uninstall devices
Package, rig and remove equipment to new facility
EPA-certified hazardous materials disposal
Legacy site clean up
Contingency planning for unplanned event
Management of any subcontractor services.
Recycle or properly dispose of all fuels, refrigerants, suppressants and components as required
Determine any surplus market valuation
Install & commission equipment in new location
Maintenance-Service Peer Review
Setting service industry benchmark standards, SBS offers a 'Peer Review' program as a check and balance to ensure you are receiving the service and maintenance to which you are entitled as compared to IEEE, ANSI, OSHA, JIC and OEM guidelines. SBS will review your service reports for completeness and value. We will statiscally sample and inspect devices to verify calibrations, measurements and procedures. Your preventative maintenance program will be evaluated for frequency and thoroughness. You will be made aware of best practices and potential enhancements to your maintenance or service. SBS will bring "a fresh set of eyes" to examine your equipment as a total system. And perhaps most import, SBS can provide a 'second opinion' when a major retrofit or replacement has been suggested by others. Should our conclusions, prepared by our Engineering Services Department, differ from your existing, we are prepared to award performance guarantees to our well-considered recommendations when implemented.
UTILITIES - CRITICAL DATA POWER - TELECOMMUNICATIONS - MOTIVE POWER
TRENDS IN CRITCAL DATA POWER
Is your data center prepared for the expected growth in power consumption? SBS can provide a power surety system that will supply your requirements & expand with your terabyte flow! According to the latest EPA report, typical data centers are consuming 40-100W per square foot. By the beginning of 2007, the IT environment was consuming 61 billion kW/h of electricity at a cost of $4.5 billion dollars representing 1.5% of total US electricity consumption. Even with the peak electrical demand of the 'average' server only reaching 251W, by the year 2011 the data center will be consuming >110 billion kW/h. This means that your power requirements will undoubtedly double over the next 5 years! Now is the time to plan for a power system that will grow as you do. SBS can transition your facility into a more efficient three-phase electrical architecture that will accommodate system gowth via incremental paralleling architecture. SBS can craft a cost effective design that will save you money while allowing true future scalability. Call SBS engineering services at 800-554-2243 ext. 309 to receive a design evaluation today.