E-AGM Series: Modular Battery Systems

2 Volt E-AGM Modular Battery Systems 200 - 3,000 Ah

AGM battery for modular battery systems

Resources

- Battery Manual

- E-AGM Rack Manual

MSDS VRLA - MSDS (SDS)

manual - Battery Capacity Testing

Applications

  • Telecom
  • Utility
  • Oil & Gas
  • Solar / Photovoltaic
  • UPS
  • Emergency Lighting
  • Railways

The E-AGM 2 Volt batteries have a similar design as the classic AGM batteries, however they are built in cases that are taller and thinner allowing a more compact footprint especially in larger Ah systems. These batteries must be ordered with the horizontal seismic modular ‘EOS’ racks, and these systems include solid intercell connectors as well as removable Plexiglas covers.

Features

  • 15–20 year design life at 77° F
  • Cycle life at 77° F
    • 1200 cycles @ 80% DOD
    • 2250 cycles @ 50% DOD
  • 100% capacity upon delivery
  • Maintenance free — no watering required
  • No corrosive fumes — special battery room not required
  • Seismic modular racking
  • Tank formed plates provide consistent and stable voltages
  • Extra space in jars for grid growth to enhance battery life
  • UL Listed - UL file no. MH19767
  • E-AGM- 200–600 Ah battery systems are typically in stock

E-AGM Battery Systems

agm VRLA seismic battery rack

Solid intercell bars come standard for EOS type racks.

fully insulated battery system with shields covers intercell bar

Construction

Positive Plate Flat plate with lead-calcium/tin grid alloy
Negative Plate Flat plate with lead-calcium grid alloy
Separator Absorbent glass mat (AGM)
Container UL 94 HB plastic resin (flame retardant UL 94 V0 optional)
Safety Valve Self resealing, pressure regulated and explosion proof
Terminals High conductivity lead-plated, with brass insert
Modular Racking Seismic rated, acid resistant, epoxy coated
Temp. Range 5° to 130° F (68° to 77° F recommended)
Float Voltage 2.25 V/cell
Equalize Voltage 2.35 V/cell
Mounting Orientation Horizontal only
Plexiglas Shields Included with rack kit
Intercell Connectors Lead plated copper bars (included with modular rack kit)

Technical Data

Battery Part No. 8Hr Ah Rate
to 1.75 V/cell
L x D x H
(in.)
Weight
(lb.)
Internal Resistance (mOhms) Terminal Type
E-AGM-200 200 3.72 x 7.26 x 14.7 29.7 0.67 M8
E-AGM-300 300 4.84 x 7.26 x 14.7 40.7 0.47 M8
E-AGM-400 400 6.54 x 7.26 x 14.7 53.9 0.35 M8
E-AGM-500 500 7.66 x 7.26 x 14.7 64.9 0.33 M8
E-AGM-600 600 8.78 x 7.26 x 14.7 77.0 0.28 M8
E-AGM-800 800 6.06 x 9.02 x 22.3 115 0.21 M8
E-AGM-1000 1000 7.32 x 9.02 x 22.3 137 0.18 M8
E-AGM-1200 1200 8.86 x 9.02 x 22.3 165 0.17 M8
E-AGM-1500 1500 10.5 x 9.02 x 22.3 203 0.14 M8
E-AGM-2000 2000 13.8 x 9.17 x 22.3 267 0.11 M8
E-AGM-3000 3000 19.6 x 14.3 x 14.7 385 0.10 M8

For UL VO 94 flame retardant containers and covers add '-FR' after part number. (Example: E-AGM-200-FR)

E-AGM Seismic Modular Racks for 48 Vdc Systems

Battery Type Rack Part No. Rack Weight (lb.) L x D x H (in.)
E-AGM-200 24xEOS200-RACK 341 35 x 17 x 42
E-AGM-300 24xEOS300-RACK 363 35 x 17 x 50
E-AGM-400 24xEOS400-RACK 377 35 x 17 x 59
E-AGM-500 24xEOS500-RACK 403 35 x 17 x 66
E-AGM-600 24xEOS600-RACK 429 35 x 17 x 73
E-AGM-800 24xEOS800-RACK 810 42 x 25 x 57
E-AGM-1000 24xEOS1000-RACK 847 42 x 25 x 64
E-AGM-1200 24xEOS1200-RACK 924 42 x 25 x 73
E-AGM-1500 24xEOS1500-RACK 968 65 x 25 x 57
E-AGM-2000 24xEOS2000-RACK 1023 66 x 25 x 70

E-AGM Seismic Modular Racks for 125 Vdc Systems

Battery Type Rack Part No. Rack Weight (lb.) L x D x H (in.)
E-AGM-200 60xEOS200-RACK 1023 85 x 17 x 42
E-AGM-300 60xEOS300-RACK 1089 85 x 17 x 50
E-AGM-400 60xEOS400-RACK 1129 85 x 17 x 59
E-AGM-500 60xEOS500-RACK 1208 85 x 17 x 66
E-AGM-600 60xEOS600-RACK 1287 85 x 17 x 73
E-AGM-800 60xEOS800-RACK 2429 107 x 25 x 57
E-AGM-1000 60xEOS1000-RACK 2541 107 x 25 x 64
E-AGM-1200 60xEOS1200-RACK 2772 107 x 25 x 73
E-AGM-1500 60xEOS1500-RACK 2904 163 x 25 x 57
E-AGM-2000 60xEOS2000-RACK 3069 165 x 25 x 70

Other/custom rack arrangements available