Language:  
 
 
 
 
 
 
 
  Advanced Search
 
 
Search Our Site.
 
 

DC POWER SYSTEMS, RECTIFIERS & INVERTERS
Modular, Hot-Swappable & Independent 24v & -48v

OSP, CO, Wireless, Cellular, Broadband w/ UL, NEBS or Telcordia

 modular 48vdc 500w rectifier power shelf      Telecom power rack 1200A with distribution  48v dc power plant 9000A rectifiers & distribution

Modular Rectifiers & Shelves

  • N+1 redundant hot-swappable, solid state digitally controlled switch-mode design
  • 168W - 3000W, 10A -100A, 24v & -48v modules, temperature compensated 
  • rack (19" or 23") or bay mountings
  • Bellecore (TR-TSY), Telcordia compliance, UL/CSA listings
  • TCP/IP communications & alarm contacts
  • Load sharing/sensing individually, available master control module
  • Distribution shelf w/ LVD
  • Argus, Magnetek, Emerson, Marconi, Tyco, Helios, Valare, Alcatel, Lucent, Reltec, Lorain & more
  • New, surplus & refurbished 

Rectifier, 168w, 48v modular Rectifier shelf 168w rectifier, 1300w, 48v modular rectifier shelf, 1400w Rectifier 1400w, 48v modular dc distribution shelf, 500A Digital rectifier supervisory controller

DC Power Frames

  • N+1 redundant hot-swappable, solid state digitally controlled switch-mode design
  • 50A - 500A,  24v & -48v systems, temperature compensated 
  • relay racks, network racks, 19" & 23"
  • Bellecore (TR-TSY), Telcordia compliance, UL/CSA listings
  • TCP/IP communications & alarm contacts
  • Load sharing/sensing master control module
  • Distribution shelf w/ LVD 
  • Argus, Magnetek, Emerson, Marconi, Tyco, Helios, Valare, Alcatel, Lucent, Reltec, Lorain & more
  • New, surplus & refurbished 

 DC power frame, rack/wall mount, enclosedDc power frame, 100A, 48v relay rack  Rectifier power system, 48v, 3000w    DC power frame 50A - 500A 48v

DC Power Plant

  • N+1 redundant hot-swappable, solid state digitally controlled switch-mode design
  • 250A - 3000A,  24v & -48v systems, temperature compensated
  • complete power bays
  • Bellecore (TR-TSY), Telcordia compliance, UL/CSA listings
  • TCP/IP communications & alarm contacts
  • Load sharing/sensing master control module
  • Distribution shelf w/ LVD 
  • Argus, Magnetek, Emerson, Marconi, Tyco, Helios, Valare, Alcatel, Lucent, Reltec, Lorain & more
  • New, surplus & refurbished  
                                                DC power plant, 48v, 750A with controls, communications & distribution                   DC power plant, 48v, 3000A, with distribution, communications    

Inverters - Frame & Shelf

  • Output capacities  20kW/120-1vac; 40kW/240-1vac; 60kW/208-3vac adj to +/- 5%, 0.1% Hz. regulation, 2%THD
  • 1000W redundnant N+1 hot-swappable modules, microprocessor digitally controlled
  • Switch-mode power electronics for true sinusoidal output
  • Cage sizes 7", 9", 19", 23"
  • Client power modules, server control module, alarming module, AC bypass transfer switch
  • 24v, 48v & 125v nominal DC input,  0.5% regulation
  • Under voltage-UV, over voltage- OV, short circuit-SC & Thermal protection, forced air cooling
  • Magnetek, Argus, Eltek, Majorsine, MGE, Tyco, LaMarche & more 

Single Phase Inverters                                             Three pahse invert

 

 

   G Series gel-cell VRLA batteries     VRZ series 2v gel-cell batteries     AGM Series VRLA front access battery       SBS UPS series high rate VRLA batteries
VRLA Telecom Batteries System Solutions

 

DC to AC Power Inverters

SBS offers a variety of inverters ranging from 1kVA to 10kVA in several design topologies including transformer based, ferro-resonnant as well as switch-mode MOSFET.  Used to convert available DC power supplied by large rectifier & battery systems to nominal 120 volt AC power for discrete computer & other office loads, the inverter is extremely popular within the telecommunications environment.  Because the DC power buss is reserve in nature, a virtually uninterrupted power supply is created for PC workstations, SCADA systems, alarm panels, security devices & fire protection systems.  The most popular & economical units are the 1 kVA (25A) & 2 kVA (50A) styles in electronic switch-mode (SMPS) design.

1-2kVA Rack Mount Inverters                                              dc to ac inverters from SBS

  • 24, 48 & 125 vdc nominal input
  • 120, 208, 230 & 240 vac output
  • integral AC bypass switch
  • 19" & 23" rack mounting
  • optional SNMP communications
  • hardwire input
  • UL certification
  • >85% efficiency
  • transistorized IGBT sinewave output
  • high MTBF                                                                        Inverter Spec
 
 
 

 

 

 

SBS can design a solution to replace or work in parallel with other DC Plant such as Helios, Lucent, Tyco, Marconi, Argus, Delta, Alcatel, Reltek, Valare, Magnetek, Emerson Network Power, Lamarche & others.  SBS specializes is design, providing & installing 48v & 24v DC power systems & their associated 20 year VRLA or 20 year flooded wet cell batteries for telecommunications, solar, wind & network power applications.

 
 
 

 

Storage Battery Systems Inc.© Copyright 2006 | International (011-1-262-703-5800) | 800-554-2243 | FAX 262-703-3073 | sbs@sbsbattery.com